Biomedical Waste Incinerator
Kease Sustainable Solutions
Biomedical Waste Incinerator
Medical waste incineration involves the burning of wastes produced by hospitals, veterinary facilities, and medical research facilities. These wastes include both infectious medical wastes as well as non-infectious, general housekeeping wastes. Incineration is the process of burning hazardous materials at temperatures high enough to destroy contaminants. Incineration is conducted in an “incinerator,” which is a type of furnace designed for burning hazardous materials in a combustion chamber.
Current Bio Medical Waste Disposal Problem
- High Cost for Disposition
- Time Taking Process
- Waste can be dangerous for hospital employee’s health
- Dependency on third party agencies
- Extra cost for transportation and employees
Our Solution for the Problem
- Onsite Disposal of Bio Medical Waste saves Manpower and Cost
- Real Time disposal
- Reduces dependency on third-party vendors
- Smoke elimination which can eliminate 95% of smoke which helps to dispose of without pollution
- Reusable Carbon and Ash Production at the same time
- Waste will be disposed at the 1200 Degree temperature as per WHO & MPCB Norms
Product Specification
| Type of Incinerator | Electric |
| Material of outer body | Mild Steel |
| Material on Inner Chambers (primary & secondary) | Mild Steel |
| Machine Dimensions | 2000 W x 500 D x 1000 H (MM) |
| Primary Chamber Dimension | 500 W x 500 D x 1000 H (MM) |
| Secondary Chamber Dimension | 500 W x 500 D x 1000 H (MM) |
| ESP Smoke Holding Chamber Dimension | 500 W x 500 D x 400 H (MM) |
| Machine Weight | 400-500 KG |
| No. of Absorption Chambers | 8 |
| Primary Chamber Temperature | 800 to 900 Degree Centigrade with Auto Power Cutoff |
| Insulation | 1425 Degree centigrade Ceramic Boards |
| Primary Chamber Thickness | 3 MM |
| Secondary Chamber Thickness | 5 MM |
| Outer Body Thickness | 1.2 MM |
| Safety Measures | 3 MCB |
| Secondary Chamber Retention time | More than 2 seconds |
| CPCB incinerator emission norms compatibility | Yes |
| Power Supply | 230v 16 Amps Single Phase |
| Synchronize Primary and Secondary temperature control | Yes |
| Incineration Capacity | 100 ltr |
| Smoke Treatment Technology | ESP with Corona effect |
| Combustion Efficiency | 99% |
| Insulation Thickness | 115mm |
| Stand Provided | Yes, with lockable wheels |
| All Weather Protection | Yes |
| Temperature Display | Yes |
| Temperature Control | Yes |
| Primary Chamber Heater WATT | 5000W |
| Secondary Chamber Heater Watt | 3000W |